Indoor AMZ-0.66 series epoxy resin cast insulation through-core current transformer is suitable for power measurement, current detection and relay protection of ring network cabinet below 35KV and AC 50/60Hz.

Technical parameters


Model Rated primary current (A) Rated secondary current (A) Accuracy level or combination of accuracy levels Rated output (VA)
AMZ-0.66W1 7.2~28.8 0.075~0.3(S1,S2 winding) 0.288~1.152(C,D winding) 10P80  EXTD.1000%   0.1
AMZ-0.66W2 14.4~57.6
AMZ-0.66W3 28.8~115.2 5P80  EXTD.1000%
AMZ-0.66W4 57.6~230.4
AMZ-0.66W5 115.2~460.8

 

Products meet the standard GB20840.1, GB20840.2, IEC61869-1, IEC61869-2

If users have special requirements, they can be determined after consultation with our company.

The above technical parameters are not the final technical commitment, please be confirmed by our technical personnel.

Product Information


Product Description

Indoor AMZ-0.66 series epoxy resin cast insulation through-core current transformer is suitable for power measurement, current detection and relay protection of ring network cabinet below 35KV and AC 50/60Hz.

Conditions of use

Installation location: indoor.

Ambient temperature:-25 ℃ ~ 40 ℃, daily average temperature is not more than 30 ℃.

Altitude: ≤ 1000m, higher altitude can be selected as required.

Humidity: The maximum relative humidity at room temperature is 95%.

There shall be no violent vibration or collision at the installation site.

Structural Overview

Through-core, fully enclosed, epoxy resin cast insulated current transformer.

The primary terminal is identified as P1 and the secondary terminal is identified as S1-S2,C-D this model has 4 secondary terminals and supports up to 2 secondary windings.

Technical Data

The installation site is free of gas, steam, chemical deposition, explosion and corrosive media that seriously affect the insulation of the transformer.

Power frequency withstand voltage between secondary windings and grounding 3kV/1min.

Other requirements shall be in accordance with GB20840.1, GB20840.2, IEC61869-1 and IEC61869-2.

Application Case


Outdoor transformer application case

Outdoor transformer application case

Outdoor transformer application case

Outdoor transformer application case

Outdoor transformer application case

Outdoor transformer application case

Outdoor transformer application case

Outdoor transformer application case

Key words:

TLEP

Get Quote


We will be happy to provide you with quality products and services

Submit